Elevations must be drawn to an acceptable scale. Label each exhibit appropriately
and reference them to plans. Include front, rear, and side elevations, including patio
covers, decks, and fireplaces. Label finished grades, interior and exterior finished
floor. Provide vertical dimensions from interior finish floor to top of plate, window
sill, or header. Specify finish materials (stucco, concrete block, roofing systems,
siding, veneers, etc.). Label roof slopes. Dimension length of horizontal projection
of eaves. Display building height, in accordance with Austin City Code. Label high
and low point of grade adjacent to structure, average adjacent grade, and vertical
distance to applicable roof point.