§ 8.4.0. DETENTION POND STORAGE DETERMINATION  


Latest version.
  • A flow routing analysis using detailed hydrographs must be applied for all detention pond designs. The Soil Conservation Service hydrologic methods (TR-20) and the Hydrologic Engineering Center (HEC) hydrologic methods (HEC-HMS) may be used. The engineer may use other methods but must have their acceptability approved by the Director.