§ 410S.2. Submittals  


Latest version.
  • The submittal requirements of this specification item may include:

    Appropriate mix designs for class of concrete for each type of structure or unit;

    Appropriate mortar and grout mix designs;

    Product name, description, technical information and supplier of any acrylic-polymer latex admixture;

    Type, supplier and certified test results for expansion joint materials;

    Type of waterstop and confirmation that the product conforms to TxDoT DMS-6160;

    Type and manufacturer of proposed evaporation retardant and confirmation that it meets the requirements of test results for TxDoT DMS-4650;

    Type and manufacturer of proposed chemical admixtures and confirmation that it meets the requirements of test results for TxDoT DMS-4640;

    Type and manufacturer of proposed curing admixtures and confirmation that it meets the requirements of test results for TxDoT DMS-4640;

    Type and manufacturer of proposed chemical admixtures and confirmation that it meets the requirements of test results for TxDoT DMS-4640;

    Type and manufacturer of proposed epoxy and/or adhesives and confirmation that it meets the requirements of test results for TxDoT DMS-6100;

    Reinforcing steel shall conform to Standard Specification Item No. 406S, "Reinforcing Steel".

    Contractors formwork plan for placing and consolidating concrete around wall penetrations and at locations designated as having congested reinforcing steel.