§ 505S.3. Materials  


Latest version.
  • A.

    Portland Cement Concrete

    The Portland cement concrete shall conform to Class D Concrete, Item No. 403, "Concrete for Structures."

    B.

    Pipe

    Portland Cement concrete pipe shall conform to ASTM C-76, Class III or better.

    Corrugated Metal Pipe (CMP) shall conform to Section 510. 2 (8)(o) of the City of Austin Standard Specification Item No. 510, "Pipe."

    Steel Pipe shall conform to ASTM A134 with a minimum thickness of 3/8 inch (9.5 mm) for pipe with a diameter of 16 inches (400 mm) and greater.

    C.

    Grout

    Grout shall consist of not less than 6 sacks Portland cement per cubic yard (335 kilograms Portland cement per cubic meter) and clean washed sand mixed with water. The grout shall have a consistency such that the grout will flow into and completely fill all voids. If allowed by the Engineer or designated representative, an air entraining admixture may be added to facilitate placement.