Austin |
Building Criteria Manual |
Section 5. COMMERCIAL CONSTRUCTION - MECHANICAL, ELECTRICAL, PLUMBING AND OTHER TECHNICAL CODES |
Appendix 5.2.0. ELECTRICAL CODE |
§ 5.2.4. WIRING OVER AND UNDER NAVIGABLE WATER
This rule is promulgated to administer and implement Section 555 of the Electrical Code.
The following electric installation requirements shall apply on navigable waters in the corporate city limits:
A minimum of one (1) light station is required along each exterior side of the facility for each 50 feet in the dimension of structure which runs parallel to the shoreline and for each 30 feet which runs perpendicular to the shoreline. Only one (1) light station is required for a dock which is 50 feet or less, is of parallel length and is 30 feet or less from the shoreline.
If only one (1) light station is required, it must be on the end or side farthest from the shoreline.